Indian Journal of Pharmaceutical Sciences
Users online: 46
Scientific Publication of the Indian Pharmaceutical Association
Home Email this page Print this page Bookmark this page Decrease font size Default font size Increase font size
The Journal Search Current Issue Archives Instructions Online submission Login  


 
RESEARCH PAPER
Year : 2007  |  Volume : 69  |  Issue : 2  |  Page : 202-205
Development and validation of a HPTLC method for the simultaneous estimation of telmisartan and hydrochlorothiazide in tablet dosage form


1 Shri B. M. Shah College of Pharmaceutical Education & Research, Modasa - 383 315, India
2 L. M. College of Pharmacy, Ahmedabad - 380 009, India
3 Shri B. M. Shah College of Pharmacy, Modasa - 383 315, India

Date of Submission28-Sep-2005
Date of Decision21-Aug-2006
Date of Acceptance16-Mar-2007

Correspondence Address:
N J Shah
Shri B. M. Shah College of Pharmaceutical Education & Research, Modasa - 383 315
India
Login to access the Email id


DOI: 10.4103/0250-474X.33143

Get Permissions

   Abstract 

A simple, precise, accurate and rapid high performance thin layer chromatographic method has been developed and validated for the estimation of telmisartan and hydrochlorothiazide simultaneously in combined dosage forms. The stationary phase used was precoated silica gel 60F254. The mobile phase used was a mixture of chloroform: methanol: toluene (2:5:5 v/v/v). The detection of spots was carried out at 272 nm. The method was validated in terms of linearity, accuracy, precision and specificity. The calibration curve was found to be linear between 250 to 500 ng/spot for telmisartan and 200 to 700 ng/spot for hydrochlorothiazide. The limit of detection and the limit of quantification for the telmisartan were found to be 75 and 190 ng/spot, respectively, and for hydrochlorothiazide 55 and 150 ng/spot, respectively. The proposed method can be successfully used to determine the drug content of marketed formulation.



How to cite this article:
Shah N J, Suhagia B N, Shah R R, Shah P B. Development and validation of a HPTLC method for the simultaneous estimation of telmisartan and hydrochlorothiazide in tablet dosage form. Indian J Pharm Sci 2007;69:202-5

How to cite this URL:
Shah N J, Suhagia B N, Shah R R, Shah P B. Development and validation of a HPTLC method for the simultaneous estimation of telmisartan and hydrochlorothiazide in tablet dosage form. Indian J Pharm Sci [serial online] 2007 [cited 2013 May 25];69:202-5. Available from: http://www.ijpsonline.com/text.asp?2007/69/2/202/33143


The combination of telmisartan and hydrochlorothiazide has recently been introduced in the market. Chemically telmisartan is 3-N 1 -methyl-2-benzimidazole derivative of N 1 -4-(2-carboxyphenyl phenyl)-2-propyl, 4-methyl benzimidazole[1],[2] and hydrochlorothiazide is 6-chloro-3, 4-dihydro-2H-1, 2, 4-benzothiadiazine-7-sulphonamide-1,1-dioxide. Telmisartan is a new angiotensin II receptor antagonist for the treatment of essential hypertension. It is useful in the treatment of mild to moderate hypertension, well tolerated with a lower incidence of cough than ACE inhibitors[3]. The addition of hydrochlorothiazide to telmisartan was more effective than each agent at lowering blood pressure in patients with hypertension[4]. Literature survey reveals that few HPLC methods are reported for the estimation of telmisartan and hydrochlorothiazide in the biological fluids[5],[6] and formulations[7]. So far no HPTLC method has been reported for the estimation of telmisartan and hydrochlorothiazide in formulation. In the present investigation an attempt has been made to develop accurate and precise HPTLC method for the simultaneous estimation of telmisartan and hydrochlorothiazide in combined dosage forms.


   Materials and Methods Top


Telmisartan and hydrochlorothiazide standard were procured as a gift sample from Sun Pharmaceuticals Ltd., Baroda. Silica gel 60F 254 TLC plates (10 × 10 cm, layer thickness 0.2 mm, E. Merck, Mumbai) were used as a stationary phase. All chemicals and reagents used were of analytical grade. Tablets containing telmisartan (40 mg) and hydrochlorothiazide (12.5 mg) were purchased from local market (Telsar-H, Unichem Labt. and Telpres-H, Nicholas Piramal India Ltd). A Camag HPTLC system comprising of Camag Linnomate V automatic sample applicator, Hamilton syringe (100 µl), Camag TLC Scanner 3, Camag WinCATS software, Camag Twin-trough chamber (10×10 cm) and ultrasonicator were used during study.

Preparation of standard and sample solutions:

Telmisartan and hydrochlorothiazide (25 mg) each were weighed accurately, dissolved and diluted with chloroform to obtain the final concentration of 100 µg/ml of each drug. Twenty tablets were weighed accurately and ground to fine powder. Weight equivalent to 25 mg of telmisartan and hydrochlorothiazide were transferred to conical flask and mixed with chloroform. The solution was sonicated for 15 min. The extracts were filtered through Whatmann filter paper No. 41 and residue was washed with chloroform. The extracts and washing were pooled and transferred to a 250 ml volumetric flask and volume was made up to 250 ml with chloroform. Required dilutions were made to get 100 µg/ml of telmisartan and hydrochlorothiazide.

HPTLC method and chromatographic conditions:

TLC plates were prewashed with methanol. Activation of plates was done in an oven at 50 0 for 5 min. The chromatographic conditions maintained were precoated silica gel 60F 254 aluminum sheets (10 × 10 cm) as stationary phase, chloroform: methanol: toluene (2:5:5 v/v/v) as mobile phase, chamber and plate saturation time of 30 min, migration distance allowed was 72 mm, wavelength scanning was done at 272 nm keeping the slit dimention at 5×0.45 mm. A deuterium lamp provided the source of radiation. Four microlitres of standard solutions of telmisartan and hydrochlorothiazide were spotted and developed at constant temperature. Wavelength was selected by scanning standard solutions of both drugs over 200 nm to 400 nm wavelengths. Telmisartan show maximum absorbance at 299 nm and hydrochlorothiazide at 277 nm. Both components show reasonably good response at 272 nm, therefore photometric measurements were performed at 272 nm in reflectance mode with Camag TLC scanner 3 using Win CATS software.

Aliquots of 2.5, 3.0, 3.5, 4.0, 4.5, 5.0 µl of standard solution of telmisartan and 2.0, 3.0, 4.0, 5.0, 6.0, 7.0 µl of hydrochlorothiazide were applied on the TLC plate (100 µg/ml of drug). TLC plate was dried, developed and analyzed photometrically as described earlier. The standard calibration curve was generated using regression analysis with Microsoft excel.

Validation of the method[8],[9],[10]:

The developed method was validated in terms of linearity, accuracy, limit of detection, limit of quantification, intra-day and inter-day precision and repeatability of measurement as well as repeatability of sample application.

Analysis of the marketed formulations:

Four microlitres of sample solutions of the marketed formulation was spotted on to the same plate followed by development scanning. The analysis was repeated in triplicate. The content of the drug was calculated from the peak areas recorded.


   Results and Discussion Top


A solvent system that would give dense and compact spots with significant Rf values was desired for quantification of telmisartan and hydrochlorothiazide in pharmaceutical formulations. The mobile phase consisting of chloroform: methanol: toluene (2:5:5 v/v/v) gave R f values of 0.53±0.04 and 0.68±0.03 for telmisartan and hydrochlorothiazide, respectively [Figure - 1]. The linear regression data (n=5, [Table - 1]) showed a good linear relationship over a concentration range of 250-500 ng/spot and 200-700 ng/spot for telmisartan and hydrochlorothiazide, respectively. The limit of detection and limit of quantification for telmisartan was found to be 75 and 190 ng/spot and for hydrochlorthiazide, 55 and 150 ng/spot, respectively.

The intra-day precision was determined by analyzing standard solutions in the concentration range of 250 ng/spot to 500 ng/spot for telmisartan and 200 ng/spot to 700 ng/spot for hydrochlorothiazide for 3 times on the same day while inter-day precision was determined by analyzing corresponding standards daily for 3 day over a period of one week. The intra-day and inter-day coefficients of variation are given in [Table - 2]. Repeatability of sample application was assessed by spotting 4 µl of drug solution 5 times on a TLC plate followed by development of plate and recording the peak area for 5 spots. The % RSD for peak area values of telmisartan and hydrochlorothiazide were found to be 1.17 and 1.53, respectively. Repeatability of measurement of peak area was determined by spotting 4 µl of telmisartan and hydrochlorothiazide solution on a TLC plate and developing the plate. The separated spot was scanned five times without changing the position of the plate and % RSD for measurement of peak area of telmisartan and hydrochlorothiazide were found to be 0.55 and 0.34, respectively. To confirm the specificity of the proposed method, the solution of the formulation was spotted on the TLC plate, developed and scanned. It was observed that the excipients present in the formulation did not interfere with the peaks of telmisartan and hydrochlorothiazide.

Recovery studies of the drugs were carried out for the accuracy parameter. These studies were carried out at three levels i.e. multiple level recovery studies. Sample stock solution from tablet formulation of 100 µg/ml of were prepared. Dilutions were made and recovery studies were performed. % Recovery was found to be within the limits as listed in [Table - 3]. The assay value for the marketed formulation was found to be within the limits as listed in [Table - 4]. The low RSD value indicated the suitability of the method for routine analysis of telmisartan and hydrochlorothiazide in pharmaceutical dosage forms.

The developed HPTLC technique is simple, precise, specific and accurate and the statistical analysis proved that method is reproducible and selective for the analysis of telmisartan and hydrochlorothiazide in bulk drug and tablet formulations.


   Acknowledgements Top


The authors thank the Sun Pharmaceuticals Ltd., Baroda for the gift sample of telmisartan and hydrochlorothiazide. Authors also thank the principal and the management for providing necessary facilities and encouragement.

 
   References Top

1.Ramsay, L.E., Brit. Med. J., 1999, 635, 1993.  Back to cited text no. 1    
2.McClellan, K.J. and Markham, A., Drugs , 1998, 56, 1044.  Back to cited text no. 2    
3.Anon., The Formulary , 1999, 18.  Back to cited text no. 3    
4.McGill, J.B. and Reilly, P.A., Clin. Cardiol., 2001, 24, 72.  Back to cited text no. 4    
5.White, W.B., Weber, M.A., Davidai, G., Neutel, J.M., Bakris, G.L. and Giles, T., Blood Press. Monit, 2005, 10, 163.  Back to cited text no. 5    
6.Alocer, L., Fernandez, P., Campos, E., Ruiz, R.O., Bahena, J., Dela, J.J. and Segovia, A.C., Int. J. Clin. Pract. , 2004, 58, 39.  Back to cited text no. 6    
7.Palled, M.S., Rajesh, P.M.N., Chatter, M. and Bhat, A.R., Indian J. Pharm. Sci., 2005, 5, 108.   Back to cited text no. 7    
8.El-Gindy, A., El-Waily, A.F.M. and Bedari, M.F., J. Pharm. Biomed. Anal., 2000, 23, 341.  Back to cited text no. 8    
9.Validation of Analytical Procedures, Methodology, ICH harmonized tripartite guidelines, 1996, 1.  Back to cited text no. 9    
10.Thoppil, S.O., Cardoza, R.M. and Amin, P.D., J. Pharm. Biomed. Anal., 2001, 25, 15.  Back to cited text no. 10    


    Figures

  [Figure - 1]
 
 
    Tables

  [Table - 1], [Table - 2], [Table - 3], [Table - 4]

This article has been cited by
1 UV-spectrophotometric method for estimation of telmisartan in bulk and tablet dosage form
Pandey, A., Sawarkar, H., Singh, M., Kashyap, P., Ghosh, P.
International Journal of ChemTech Research. 2011; 3(2): 657-660
[Pubmed]
2 Development and validation of spectrophotometric and ion pair chromatographic techniques for estimation of telmisartan and hydrochlorothiazide
Bhatia, N.M., Shinde, H.V., Bhatia, M.S., Choudhari, P.B., Ingale, K.B.
Ars Pharmaceutica. 2010; 51(3): 145-154
[Pubmed]
3 Simultaneous UV spectrophotometric determination of Atorvastatin calcium and Telmisartan in tablet dosage form
Vijayalakshmi, R., Magesh, A.R., Dhanaraju, M.D.
Oriental Journal of Chemistry. 2010; 26(1): 255-258
[Pubmed]
4 Stability indicating HPTLC method for simultaneous determination of Telmisartan and Ramipril in tablets
Lakshmi, K.S., Sivasubramanian, L., Pal, K.
International Journal of Pharmacy and Pharmaceutical Sciences. 2010; 2(SUP 4): 127-129
[Pubmed]
5 A validated densitometric method for analysis of Telmisartan and Atorvastatin calcium in fixed dose combination
Patil, U.P., Gandhi, S.V., Sengar, M.R., Rajmane, V.S., Gandhi, S.V.
Journal of the Chilean Chemical Society. 2010; 55(1): 94-96
[Pubmed]
6 Simultaneous spectrophotometric estimation of amlodipine besylate and telmisartan in tablet dosage form
Thomas, A.B., Jagdale, S.N., Dighe, S.B., Nanda, R.K.
International Journal of PharmTech Research. 2010; 2(2): 1334-1341
[Pubmed]
7 Stability indicating LC method for simultaneous determination of irbesartan and hydrochlorothiazide in pharmaceutical preparations
Rane, V.P., Patil, K.R., Sangshetti, J.N., Yeole, R.D., Shinde, D.B.
Journal of Chromatographic Science. 2010; 48(7): 595-600
[Pubmed]
8 Simultaneous determination of atorvastatin calcium and telmisartan in tablet dosage form by spectrophotometry
Patil, U.P., Gandhi, S.V., Sengar, M.R., Rajmane, V.S.
International Journal of ChemTech Research. 2009; 1(4): 970-973
[Pubmed]
9 Extractive spectrophotometric method for the estimation of telmisartan in tablets
Vijayalakshmi, R., Applaraju, N., Dhanaraju, M.D.
Oriental Journal of Chemistry. 2009; 25(3): 747-749
[Pubmed]
10 Ratio Spectra Derivative and Zero-Crossing Difference Spectrophotometric Determination of Olmesartan Medoxomil and Hydrochlorothiazide in Combined Pharmaceutical Dosage Form
Ambadas R. Rote, Pankaj D. Bari
AAPS PharmSciTech. 2009; 10(4): 1200-1205
[Pubmed]
11 Simultaneous high-performance liquid chromatographic determination of telmisartan and hydrochlorothiazide in pharmaceutical preparation
Rane, V.P., Sangshetti, J.N., Shinde, D.B.
Journal of Chromatographic Science. 2008; 46(10): 887-891
[Pubmed]
12 Application of UV-spectrophotometry and first order derivative methods for determination of telmisartan in bulk and tablets
Vekariya, N.R., Fursule, R.A., Shirkhedkar, A.A., Surana, S.J.
Oriental Journal of Chemistry. 2008; 24(1): 353-356
[Pubmed]
13 Determination of telmisartan by HPTLC — A stability indicating assay
Chitra Prabhu, Ganesa Sundararajan Subramanian, Arumugam Karthik, Suvarna Kini, Mallayasamy Surulivel Rajan, Nayanabhirama Udupa
JPC - Journal of Planar Chromatography - Modern TLC. 2007; 20(6): 477-481
[Pubmed]



 

Top
Print this article  Email this article
 
  Search
   
   Next article
   Previous article 
   Table of Contents
  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Article in PDF (137 KB)
    Citation Manager
    Access Statistics
    Reader Comments
    Email Alert *
    Add to My List *
* Registration required (free)  


    Abstract
    Materials and Me...
    Results and Disc...
    Acknowledgements
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed5358    
    Printed92    
    Emailed12    
    PDF Downloaded680    
    Comments [Add]    
    Cited by others 13    

Recommend this journal