Indian Journal of Pharmaceutical Sciences
Users online: 92
Scientific Publication of the Indian Pharmaceutical Association
Home Email this page Print this page Bookmark this page Decrease font size Default font size Increase font size
The Journal Search Current Issue Archives Instructions Online submission Login  


 
  Table of Contents 
RESEARCH PAPER
Year : 2011  |  Volume : 73  |  Issue : 4  |  Page : 387-391
Photo- and thermal degradation of piroxicam in aqueous solution


Department of Pharmaceutical Chemistry, Faculty of Pharmaceutical Sciences, Baqai Medical University, Gadap Road, Toll Plaza, Super Highway, Karachi-74600, Pakistan

Date of Submission16-Sep-2010
Date of Decision01-Jul-2011
Date of Acceptance08-Jul-2011
Date of Web Publication4-May-2012

Correspondence Address:
U Nazim
Department of Pharmaceutical Chemistry, Faculty of Pharmaceutical Sciences, Baqai Medical University, Gadap Road, Toll Plaza, Super Highway, Karachi-74600
Pakistan
Login to access the Email id


DOI: 10.4103/0250-474X.95615

Get Permissions

   Abstract 

Light and temperature have considerable effect on the degradation of piroxicam in aqueous solutions. The pH and acetate buffer ions also affect the degradation process. The apparent first-order rate constants for the photochemical and thermal degradation of piroxicam have been determined as 2.04-10.01 and 0.86-3.06×10−3 min−1 , respectively. The first-order plots for the degradation of piroxicam showed good linearity within a range of 20-50% loss of piroxicam at pH 2.0-12.0. The rate-pH profile for the photodegradation of piroxicam is a U-shaped curve and for the thermal degradation a bell-shaped curve in the pH range of 2.0-12.0. The thermal degradation of piroxicam was maximum around pH 6.0. It is increased in the presence of acetate ions but was not affected by citrate and phosphate ions.


Keywords: Buffer effect, kinetics, piroxicam, photodegradation, thermal degradation


How to cite this article:
Aminuddin M, Nazim U, Ahmad I. Photo- and thermal degradation of piroxicam in aqueous solution. Indian J Pharm Sci 2011;73:387-91

How to cite this URL:
Aminuddin M, Nazim U, Ahmad I. Photo- and thermal degradation of piroxicam in aqueous solution. Indian J Pharm Sci [serial online] 2011 [cited 2013 Jun 19];73:387-91. Available from: http://www.ijpsonline.com/text.asp?2011/73/4/387/95615


Piroxicam, 4-hydroxy-2-methyl-N-(2-pyridyl)-2H-1,2-benzothiazine-3-carboxamide-1,1-dioxide) [Figure 1] belongs to the class of nonsteroidal antiinflammatory drugs (NSAIDs), which is structurally unrelated but pharmacologically similar to other NSAIDs [1] . A number of degradation products of piroxicam are reported in British Pharmacopoeia [2] , including 2-aminopyridine, which has been identified as a hydrolytic product by some workers [3],[4] . The hydrolysis of cinnoxicam follows a pseudo-first order reaction as a function of temperature [5] . Some studies on the thermal degradation [5],[6],[7] and photodegradation [8],[9],[10] of piroxicam have been conducted in the solid state and in aqueous solution.
Figure 1: Structure of piroxicam

Click here to view


In the present work the degradation of piroxicam over a wide pH range under the influence of heat, light and buffers has been studied and the kinetics of theses reactions evaluated. The relation of rates of degradation with pH has been developed and the pH of maximum stability has been reported.


   Materials and Methods Top


Piroxicam was obtained from Sigma Chemical Co., 1,10-phenanthroline, ammonium iron (III) sulphate dodecahydrate, hydrochloric acid and methanol were obtained from Merck. The reagents were analytical grade from BDH. The following buffers were used throughout: KCl + HCl buffer, pH. 2.0; Citric acid + Na 2 HPO 4 , pH 3.0-7.0; Na 2 B 4 O 7 .10H 2 O +

NaOH, pH 8.0-10.0; NaHCO 3 + NaOH, pH 11.0; Na 2 HPO 4 + NaOH, pH 11.5-12.0; the ionic strength in each case was 0.05 M.

All absorbance measurements were made on a Shimadzu UV/Vis model UV-1601 spectrophotometer (range 190-1100 nm).

Assay method:

The assay of piroxicam in pure and degraded solutions was carried out by a previously reported method [11] , according to the following procedure: A 0.6 ml of the degraded solution was placed in a 10 ml volumetric flask, 8 ml of acidified 1,10-phenanthroline solution was added, the pH was adjusted to 3.5 with 0.5M NaOH/HCl and the solution made up to volume. The contents were mixed, allowed to stand for 25 min. at room temperature and the absorbance measured at 510 nm. The concentration of piroxicam in the degraded solutions was determined using a calibration curve [Figure 2]. The validity of Beer's law was confirmed in the concentration range used for the assay.
Figure 2: Calibration curve for the determination of piroxicam

Click here to view


Photodegradation:

A 10 ml aliquot of piroxicam solution (3.31 mg) was placed in a 250 ml beaker and diluted to almost 80 ml. The pH of the solution was adjusted to the desired value (2.0-12.0) with appropriate buffer. The solution was transferred to a 100 ml volumetric flask, made up to volume with the buffer and irradiated with a Philips 30 W TUV- tube fixed horizontally at a distance of 30 cm from the centre of the flask. Samples were withdrawn at appropriate intervals for spectrophotometric assay.

Thermal degradation:

A volumetric flask containing 3.31 mg/100 ml solution of piroxicam, adjusted to the desired pH value (2.0-12.0) with appropriate buffer, was placed in a thermostat water bath and heated to 100°. Samples were withdrawn at appropriate intervals, cooled to room temperature and assayed for piroxicam content.


   Results and Discussion Top


Piroxicam shows absorption maxima at 242 nm (0.1 M HCl), and 256, 290 and 358 nm (methanol) [12]. Photochemical degradation of piroxicam solution at pH 2.0 (maximum degradation) showed absorption maxima at 242 and 356 nm [12] , which gradually decreased with time, indicating the degradation of piroxicam on UV exposure. However, after 3 h the spectrum was almost stable in the 270-330 nm region. Similar spectral changes were observed in piroxicam solutions degraded in neutral and alkaline solutions.

First-order plots of log concentration versus time for the photochemical reactions (pH 2.0-12.0) showed good linearity within a range of 20-50% loss of piroxicam [Figure 3] and the rates were found to be affected by the pH of the solution [Table 1]. The rate-pH profile for the photodegradation of piroxicam is U-shaped which shows that the photodegradation may undergo specific acid-base catalysis. This results in an increase in the rate with a decrease in pH in the acid region and with an increase of rate in pH in the alkaline region. The almost constant photodegradation rate between pH 4 and 6 appears to be due to the solvent catalytic effect that is, the un-ionized water-catalyzed reaction [Table 1], [Figure 4]. The rate law for the acid-base catalyzed reaction may be written as: K obs =k 0 +k 1 [H + ]+[OH ]. At low pH, the term k 1 [H + ] is greater and specific hydrogen ion catalysis is observed. Similarly at high pH, the concentration of [OH ] is greater and specific hydroxyl ion catalysis is observed.
Figure 3: Photodegradation of piroxicam solution at pH 2.0

Click here to view
Figure 4: Rate-pH profile for the photodegradation of piroxicam

Click here to view
Table 1: Apparent first-order rate constants for the photo-degradation of piroxicam at pH 2.0-12.0

Click here to view


Many drugs undergo degradation to give U-shaped rate-pH profiles; such profiles have been observed for the degradation of penicillin [13] , cytarabine [14] , amphotericin B [15] , carbenicillin [16] , cyanocobalamin [17] , and diltiazem [18].

The spectral changes in the absorption spectra of piroxicam solution (pH 6.0) on heating at 100° for two hours showed a gradual loss of absorbance around 356 and 250 nm indicating degradation of the molecule to unknown products. The degradation may be due to the hydrolysis of piroxicam by cleavage of the amide bond attached to the 2-pyridine ring [3],[4] and the resultant absorption in the 200-400 nm regions. Similar changes were observed at other pH values.

The thermal degradation of piroxicam solution carried out at pH range 2.0-12.0 also followed first-order kinetics [Figure 5]. The apparent first-order rate constants for the reactions are reported in [Table 2]. The thermal degradation of piroxicam represents a bell-shaped pH-rate profile in the pH range 2.0-12.0 [Figure 6] showing the pH of maximum degradation around 6.0, which then slows down due to ionization of the molecule. Such curves indicate the presence of two ionisable groups in the molecule and the most reactive species is the non-ionized form [19]. The bell-shaped pH-rate profile of piroxicam shows the pH of maximum degradation at 6.0. The rate of the reaction is enhanced with pH up to 6.0 due to the pH dependent change in the rate-determining step and then slows down due to ionization of the molecule. This may be applied to the degradation of piroxicam by hydrolysis in which the rate of reaction depends on the species present at a particular pH and its variation with the ionization of the molecule.
Figure 5: Thermal degradations of piroxicam solution at p. 6.0

Click here to view
Figure 6: Rate-pH profile for the thermal degradation of piroxicam

Click here to view
Table 2: Apparent first-order rate constants for the thermal degradation of piroxicam at pH 2.0-12.00

Click here to view


Examples of bell-shaped pH-rate profiles include the hydrolysis of estrone phosphate [20] , dicarbazine [21] , hydrochlorothiazide [22] , tyrphostins [23] and decarboxylation of 4-aminosalicylic acid [24].

The Effect of buffer ions (acetate, citrate, phosphate) on the rate of thermal degradation of piroxicam (100° ) has been studied at pH 5.6 (pH max ). The citrate and phosphate ions do not exert any effect on the rate of degradation. However, the acetate ions were found to increase the rate of thermal degradation. The second-order rate constant for the base-catalyzed degradation of piroxicam in the presence of acetate ions is 1.90×10−3 M−1 min−1. Thus the presence of acetate ions in the solution containing piroxicam leads to an increase in the rate of degradation due to the catalytic effect of these ions and should be avoided in the preparation of piroxicam solutions [Table 3], [Figure 7].
Figure 7: Plot of apparent first-order rate constant for thermal degradation of piroxicam vs acetate concentration

Click here to view
Table 3: Apparent first-order rate constants for the thermal degradation of piroxicam at pH 5.6 in the presence of acetate ions

Click here to view



   Acknowledgements Top


I (U.N.) wish to express my feelings of thanks to Prof. Dr. S. Fazal Hussain, C.E.O and Dr. Shaukat Khalid, Acting Dean, Baqai Institute of Pharmaceutical Sciences, Baqai Medical University, Karachi who provided me the necessary research facilities to carry out this research work.

 
   References Top

1.Raffa RB. Analgesic-antipyretic and antiinflammatory drugs. In: Henderickson R, editor. Ramington's The Science and Practice of Pharmacy. 21 st ed. Baltimore: Lippincott Williams and Wilkins; 2006. p. 1540.  Back to cited text no. 1
    
2.British Pharmacopoeia. London: HMSO Publication; 2009. Electronic Version.  Back to cited text no. 2
    
3.Puthli SP, Vavia, PR. Stability indicating HPTLC determination of piroxicam. J Pharm Biomed Anal 2000;22:673-7.  Back to cited text no. 3
    
4.Puthli SP, Vavia PR. Stability studies of micro particulate system with piroxicam as model drug. AAPS PharmSciTech 2009;10:872-80.  Back to cited text no. 4
    
5.Ficarra R, Villari A, Micali N, Tommasini S, Calahro ML, Di Bella M, et al. Stability study of piroxicam and cinnoxicam in solid pharmaceuticals. J Pharm Biomed Anal 1999;20:283-8.  Back to cited text no. 5
    
6.Florey K, editor. Analytical Profile of Drug Substances. Vol. 15. New York: Academic Press; 1986. p. 526.  Back to cited text no. 6
    
7.Drebushchak VA, Shakhtshneider TP, Apenina SA, Drebushchak TN, Medvedeva AS, Safronoval LP, et al. Thermoanalytical investigation of drug-excipient interaction, Part 1, Piroxicam, cellulose and chitosan as starting material. J Thermal Anal Calorim 2006;84:643-9.  Back to cited text no. 7
    
8.Miranda M, Vargas F, Serrano G. Photodegradation of piroxicam under aerobic conditions, the photochemical keys of the piroxicam enigma. J Photochem Photobiol B 1991;48:199-202.  Back to cited text no. 8
    
9.Bartsch H, Eiper Kopelent-Frank H. Stability indicating assays for the determination of piroxicam comparison methods. J Pharm Biomed Anal 1999;20:531-41.  Back to cited text no. 9
    
10.Lemp E, Zanocco AL, Gunther G. Sentilized photoxygenation of piroxicam in neat solvents and solvent mixtures. J Photochem Photobiol B 2001;31:165-70.  Back to cited text no. 10
    
11.Nagaralli BS, Seetharamappa J, Melwanki MB. Spectrophotometric methods for the determination of amoxycillin, ciprofloxacin and piroxicam in pure and pharmaceutical formulations. J Pharm Biomed Anal 2002;29:859-64.  Back to cited text no. 11
    
12.Mihalic M, Hofan H, Kuftinec J, Krile B, Caplar V, Kajfez F, et al. Piroxicam. In: Florey K, editor. Analytical Profiles of Drug Substances. Vol. 15. New York: Academic Press; 1986. p. 509-31.  Back to cited text no. 12
    
13.Schwarts MA. Catalysis of penicillin hydrolysis by catechol and 3,6-bis(dimethylaminomethyl) catechols. J Pharm Sci 1964;53:1433-6.  Back to cited text no. 13
    
14.Notari RE, Chin ML, Wittbort R. Arabinosycytosine stability in aqueous solutions: pH profile and shelf life predictions. J Pharm Sci 1975;61:1189-96.  Back to cited text no. 14
    
15.Hamilton-Miller JM. The effect of pH and of temperature on the stability and bioactivity of nystatin and amphotericin B. J Pharm Pharmacol 1973;25:401-7.  Back to cited text no. 15
    
16.Zia H, Teharan M, Zargarbashi R. Kinetics of carbenicillin degradation in aqueous solutions. Can J Pharm Sci 1974;9:112-7.  Back to cited text no. 16
    
17.Ahmad I, Hussain W, Faridi AA. Photolysis of cyanocobalamin in aqueous solution. J Pharm Biomed Anal 1992;10:9-15.  Back to cited text no. 17
    
18.Won CM, Iula AK. Kinetics of hydrolysis of diltiazem. Int J Pharm 1992;79:183-90.  Back to cited text no. 18
    
19.Yoshioka S, Stella VJ. Stability of Drugs and Dosage Forms. New York: Kluwer Academic Press; 2000. p. 80-99.  Back to cited text no. 19
    
20.Kearney AS, Stella VJ. Hydrolysis of pharmaceutically relevant phosphate monoester monoanions: Correlation to an established structure-reactivity relationship. J Pharm Sci 1993;82:69-72.  Back to cited text no. 20
    
21.Shetty BV, Schowman RL, Slivak M, Riley CM. Degradation of dicarbazine in aqueous solution. J Pharm Biomed Anal 1992;10:675-83.  Back to cited text no. 21
    
22.Molica JA, Rehin CR, Smith JB. Govern HK. Hydrolysis of benzothiadiazines. J Pharm Sci 1971;60:1380-4.  Back to cited text no. 22
    
23.Won CM. Kinetics and mechanism of hydrolysis of tyrphostin. Int J Pharm 1994;104:29-40.  Back to cited text no. 23
    
24.Jivani SG, Stella VJ. Mechanism of decarboxylation of p-aminosalicylic acid. J Pharm Sci 1985;74:1274-82.  Back to cited text no. 24
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5], [Figure 6], [Figure 7]
 
 
    Tables

  [Table 1], [Table 2], [Table 3]



 

Top
Print this article  Email this article
 
 
  Search
   
  
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Article in PDF (641 KB)
    Citation Manager
    Access Statistics
    Reader Comments
    Email Alert *
    Add to My List *
* Registration required (free)  


    Abstract
    Materials and Me...
    Results and Disc...
   Acknowledgements
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed1024    
    Printed48    
    Emailed3    
    PDF Downloaded84    
    Comments [Add]    