All submissions of the EM system will be redirected to Online Manuscript Submission System. Authors are requested to submit articles directly to Online Manuscript Submission System of respective journal.

Abstract

Determination of etoricoxib in pharmaceutical formulations by HPLC method

Author(s): HM Patel, BN Suhagia, SA Shah, IS Rathod
Department of Quality Assurance, L. M. College of Pharmacy, P. B. No: 4011, Navrangpura, Ahmedabad -380 009, India

Correspondence Address:
H M Patel Department of Quality Assurance, L. M. College of Pharmacy, P. B. No: 4011, Navrangpura, Ahmedabad -380 009 India E-mail: patelhary@rediffmail.com


A simple, precise and rapid RP-HPLC method was developed for the estimation of etoricoxib in pharmaceutical dosage forms. The method was carried out on a Kromasil 100, RP-C18 column using a mixture of acetonitrile: methanol: 10mM potassium dihydrogen phosphate (pH 3.0 adjusted with orthophosphoric acid). The detection was carried out at 234 nm using rofecoxib as an internal standard. The linearity was found to be 25 to 400 ng/injection with correlation coefficient of 0.9996. The intra-day and inter-day precision (% RSD) were in the range of 0.28 to1.26 and 0.35 to 1.39, respectively. The percentage recovery was found to be 99.52±1.51 to 100.59±1.16. The result of analysis of marketed formulation was found to be 100.32±0.96 to100.95±0.69. The proposed method was successfully applied for the estimation of etoricoxib in pharmaceutical dosage forms.

Full-Text | PDF

 
 
Google scholar citation report
Citations : 69022