All submissions of the EM system will be redirected to Online Manuscript Submission System. Authors are requested to submit articles directly to Online Manuscript Submission System of respective journal.

Abstract

Estimation Of Valdecoxib In Tablets By RP-HPLC Method

Author(s): A Suganthi, H. B Sivakumar, Spana Shrikumar, M Gandhimathi, M Gopala Rao, T. K Ravi

A simple, efficient and reproducible reverse phase HPLC method has been developed for the determination of valdecoxib in tablets. The analyte was resolved by using a mobile phase (water:acetonitrile 50:50) at the flow rate of 1.2 ml/min on an isocratic HPLC system (Shimadzu) consisting of LC 10AT liquid pump, SPD 10 A UV/V is detector, Shimadzu class LC 10 A software and Water's Spherisorb ODS column (0.4x150 mm, 0.5 μ particle size) at a wave length of 237 nm. An external standard calibration method was employed for quantitation. The linearity range was 0.2-5 μg/ml for valdecoxib and the elution time was 2.4 min. The percentage recovery obtained for two brands were 100.2±0.22 and 99.6±0.24, respectively.