All submissions of the EM system will be redirected to Online Manuscript Submission System. Authors are requested to submit articles directly to Online Manuscript Submission System of respective journal.

Abstract

High performance thin layer chromatographic method for simultaneous estimation of ibuprofen and pseudoephedrine hydrochloride

Author(s): SS Chitlange1, DM Sakarkar2, SB Wankhede1, SG Wadodkar3
1Pad. Dr. D. Y. Patil Institute of Pharmaceutical Sciences and Research, Sant Tukaram Nagar, Pimpri, Pune- 411 018, India 2S. N. Institute of Pharmacy, Pusad-445 204, India 3Smt. Kishoritai Bhoyar College of Pharmacy, Kamptee, Nagpur-441 002, India

Correspondence Address:
S S Chitlange Pad. Dr. D. Y. Patil Institute of Pharmaceutical Sciences and Research, Sant Tukaram Nagar, Pimpri, Pune- 411 018 India E-mail: Sohanchitlange@rediffmail.com


High performance thin layer chromatographic method is developed for simultaneous estimation of ibuprofen and pseudoephedrine hydrochloride in tablets. Silica gel 60F 254 plates were used as stationary phase and t.butanol: ethyl acetate: glacial acetic acid: water (7:4:2:2 v/v) as mobile phase. Wavelength selected for analysis was 254 nm. Percent estimation of ibuprofen and pseudoephedrine hydrochloride was found to be 99.56% and 98.77%, respectively. Percent recovery for both the drugs was found in the range of 98.27% to 100.91%, respectively.

Full-Text | PDF

 
 
Google scholar citation report
Citations : 66710